For Rvs Campers 12V to 14.6V 14.2V 13.8V 13.5V 12.6V dc to dc charger 60A for Li-ION LiFePO4 lead acid battery
For Rvs Campers 12V to 14.6V 14.2V 13.8V 13.5V 12.6V dc to dc charger 60A for Li-ION LiFePO4 lead acid battery
DC TO DC CHARGER | Battery to Battery Charger | 12V to 14.6V 14.2V 13.8V 13.5V 12.6V 60A DC TO DC Battery Charger
< Suitable for GEL, Sealed , Flooded , LifePO4, Lithium-ion >
Function
Charge converter, "Battery to Battery (B2T/BTB)" operation, mobile operation from alternator and starter battery (Battery to Battery):
1. The powerful charge converter (booster) enables the on-board battery to be fully charged while driving.
2. It increases / decreases the voltage to the necessary level in order to provide the on-board battery with the optimum for you
3. To be able to charge the charging characteristic precisely.
4. It compensates for line losses and significant voltage fluctuations of the alternator, such as at Vehicles constantly occur, completely out.
5. The 12 V consumers supplied are protected against overvoltage and voltage fluctuations.
Apply for RVs/campers Support remote Monitor, APP control 12V to 14.6V 14.2V 13.8V 13.5V 12.6V dc to dc battery charger 60A for Li-ION / LiFePO4 / lead acid battery
Technical Parameter
Model |
WMX-B2B1260 |
MAIN BATTERY "BORD Ⅰ" |
|
Lead-Acid, Gel, AGM Batteries Nominal Voltage |
12V |
LiFePO4 Nominal Voltage |
12.8V |
lithium-ion(NCM) Nominal Voltage |
11.1V |
Capacity (Battery Size), recommended: |
90-560AH |
VEHICLE STARTER BATTERY “START II”: |
|
Vehicle Starter Battery Nominal Voltage: |
12V |
Min. Battery Capacity (Size), recommended: |
100AH |
12 V / 12 V B2B CHARGING OPERATION |
|
Input Voltage Range "Start II" ,“D+” controlled: |
10.5-16V |
Input Overvoltage Disconnection "Start II" , max.: |
16.5V |
"Bord Ⅰ" Max. charge current |
60A |
Activation Control Input "D+" |
8-16V |
Signal Output "OK/TR", Switch Position "TR", Cutoff Relay Bypass/max |
12V/1A |
"Bord Ⅰ" charging current for “start Ⅱ" |
0-5A |
Signal Output "OK/TR", Switch Position "OK" |
12V/1A |
Input "T T" for Battery Temperature Sensor "Board I": |
YES |
"Ss-" "Ss+" Inputs Sensor Cables "-" and "+" for Battery "Board I": |
YES |
stand-by current |
24mA |
Main battery overvoltage protection |
15.5V |
weight |
1.6kg |
Dimension |
190×215×70mm |
Operating temperature |
-20-50℃ |
Optional Accessories (Option) |
LCD Meter (3m cable), APP |
Battery charging Parameters
Battery Type |
Equalized charge |
Boost charge |
Float charge |
HVD |
LVD |
Constant voltage charging time |
GEL |
- |
14.3V |
13.8V |
15.5V |
11V |
2hours |
Sealed |
14.6V |
14.4V |
13.5V |
15.5V |
11V |
2hours |
Flooded |
14.6V |
14.7V |
13.5V |
15.5V |
11V |
2hours |
Life-PO4 |
- |
14.6V |
14.5V |
15.5V |
11V |
2hours |
Li-ION |
- |
12.6V |
12.5V |
13.5V |
9.3V |